WARNING: Although R 134a at normal temperature is non-toxic,
non-flammable and
not explosive in air in any mixture ratio, it is still essential to follow
various safety precautions.
The filled refrigerant circuit of the A/C system is subject to gauge
pressure. When carrying out repairs on the
A/C
Special tools required:
61 4 320
Crimping annular contacts:
Special tool 61 4 320
CRIMPING OPTICAL FIBERS
Special tools required:
61 4 320
To crimp optical fibers, use pliers 61 4 321 (1) in conjunction with crimping
head 61 4 323 (2) from crimping
set 61 4 320.
NOTE: Pliers (1) open automati