BMW X5: Air Conditioning Systems

READ NEXT:

 Air Conditioner Test (R 134A)

Before A/C efficiency test, satisfy following conditions: 1. Provide a MoDiC or DIS. Safeguard electrical system integrity by checking the fault memory (no faults in the fault memory). 2. Provide a t

 Instructions For Handling Refrigerant R 134A

WARNING: Although R 134a at normal temperature is non-toxic, non-flammable and not explosive in air in any mixture ratio, it is still essential to follow various safety precautions. The filled refrig

 Leak Testing With Ultraviolet Additives (UV Additives) (BMW Leak-Testing Case)

IMPORTANT: It is absolutely essential to read and comply with the equipment manufacturer's instructions for use provided in the equipment case! Read and comply with the instructions for use provided

SEE MORE:

 Additional Work For Camber Correction

IMPORTANT: Changes in axle geometry caused by accidents must under no circumstances be rectified by camber adjustment! NOTE: The upper control arm may only be replaced if the camber is outside the specified tolerance after toe adjustment. Adjust toe-in. Check camber values; if necessary, replace u

 Clearance And Side

REMOVING AND INSTALLING/REPLACING FRONT LEFT OR RIGHT SIDE MARKER Special tools required: 00 9 323. Necessary preliminary tasks: Remove front wheel arch cover front section. NOTE: Minimum object temperature of side marker and side panel > or = 18 ºC. If this temperature is not achieved,