BMW X5 Owners & Service Manuals

BMW X5: Park Distance Control

REMOVING AND INSTALLING (REPLACING) CONTROL UNIT (PARK DISTANCE CONTROL)

IMPORTANT: Read and comply with notes on protection against electrostatic damage (ESD protection).

Necessary preliminary tasks:

Fold insulating mat (1) to one side.

Accessories & Equipment
Fig. 1: Identifying Insulating Mat

Disconnect plug connection (1).

Remove control unit (2).

Accessories & Equipment
Fig. 2: Identifying Control Unit And Plug Connection

Replacement:

Carry out programming/coding.

REMOVING AND INSTALLING/REPLACING A FRONT ULTRASONIC TRANSDUCER (CENTRE)

Necessary preliminary tasks:

Disconnect plug connection (1) and unclip ultrasonic transducer from retaining lugs (2).

Installation:

Retaining lugs (2) must not be damaged! Make sure ultrasonic transducer is securely seated.

Accessories & Equipment
Fig. 3: Identifying Retaining Lugs And Plug Connection

REMOVING AND INSTALLING/REPLACING A FRONT ULTRASONIC TRANSDUCER (SIDE)

Necessary preliminary tasks:

Disconnect plug connection (1) and remove rubber grommet (2).

Installation:

Make sure rubber grommet (2) is securely seated.

Accessories & Equipment
Fig. 4: Identifying Rubber Grommet And Plug Connection

Unlock retaining tabs (1) in direction of arrow and pull ultrasonic transducer (2) out of holder.

Accessories & Equipment
Fig. 5: Unlocking Retaining Tabs And Ultrasonic Transducer

Installation:

Make sure rubber ring (1) is correctly seated on ultrasonic transducer (2).

Accessories & Equipment
Fig. 6: Identifying Rubber Ring

REMOVING AND INSTALLING/REPLACING A REAR ULTRASONIC TRANSDUCER (PARK DISTANCE CONTROL)

Necessary preliminary tasks:

Disconnect plug connection (1) and remove rubber grommet (2).

Installation:

Make sure rubber grommet (2) is securely seated.

Accessories & Equipment
Fig. 7: Identifying Rubber Grommet And Plug Connection

Unlock retaining tabs (1) in direction of arrow and pull ultrasonic transducer (2) out of holder.

Accessories & Equipment
Fig. 8: Unlocking Retaining Tabs And Ultrasonic Transducer

Installation:

Make sure rubber ring (1) is correctly seated on ultrasonic transducer (2).

Accessories & Equipment
Fig. 9: Identifying Rubber Ring

READ NEXT:

 Reversing Camera

INSTRUCTIONS FOR ADAPTING ADJUSTMENT UNIT FOR REVERSING CAMERA (CORGHI KDS QUICK - ACTION CLAMP) NOTE: The operation is described for the left-hand side; proceed in the same way for the right-hand si

 Night Vision

CALIBRATING REVERSING CAMERA WARNING: Danger of injury! Laser radiation at adjustment unit. Do not look into the beam! Laser class 2 As per EN 60825-1: 1994 P< or = 1 mW Lambda = 632.8 nm NOTE: Ca

 Engine And Gearbox Suspension

SEE MORE:

 Additional Work For Camber Correction

IMPORTANT: Changes in axle geometry caused by accidents must under no circumstances be rectified by camber adjustment! NOTE: The upper control arm may only be replaced if the camber is outside the specified tolerance after toe adjustment. Adjust toe-in. Check camber values; if necessary, replace u

 Removing And Installing/Replacing Rocker Arms On Left Inlet Side (N62 From 9/03 And N62TU)

Special tools required: 11 9 470 11 9 473 (cylinder bank 5 to 8) Removal of rocker arms is described separately from installation. Necessary preliminary tasks: Remove servomotor for left eccentric shaft. Remove ignition coils on cylinder bank 5 to 8. Remove left cylinder head cover. Remove